Quick answer: Air dispersion modelling for refineries means building an AERMOD model of every significant release on site: process heater and boiler stacks, the FCC regenerator, the sulphur recovery unit (SRU) tail gas incinerator, captive power, elevated and ground flares, tank farms, loading gantries, fugitive equipment leaks and the effluent treatment plant. Predicted increments of SO2, NO2, PM10, PM2.5, CO and benzene are added to the measured baseline and compared with NAAQS 2009, while H2S and other unregulated compounds are checked against recognised guideline values. Normal operation, start-up and shutdown, flaring events and the expansion case are run as separate scenarios.
Air dispersion modelling for refineries is one of the more involved jobs an EIA team can commission. A medium-sized refinery can have over a hundred emission points, from fired heaters, a catalytic cracker and sulphur recovery trains to flares, hundreds of tanks and tens of thousands of valves and flanges. The appraisal committee wants to see that the modeller has understood the process, the emission basis and the operating modes, not just typed a stack list into AERMOD.
This guide is for EHS, project and procurement teams at refineries and petrochemical plants, and EIA consultancies that outsource refinery air quality modelling.
Why AERMOD for Refineries Needs a Sector-Specific Approach
Most industrial studies are dominated by a few stacks. A refinery differs in three ways.
- Many sources of very different character. Tall, hot heater stacks sit beside ground-level tank farms and diffuse fugitive leaks. Tall stacks dominate SO2 and NOx emissions; low-level sources often dominate benzene and H2S near the boundary.
- Operating modes matter. Emissions during an SRU tail gas unit outage, a compressor trip that sends gas to the flare, or a cold start of the FCC can be many times higher than in steady operation. A study that models only normal operation leaves the most likely questions unanswered.
- Clusters are common. Indian refineries sit in coastal and industrial clusters alongside petrochemical complexes, fertiliser plants, power plants and port facilities. Cumulative assessment with neighbouring units is often written into the Terms of Reference.
If you are new to the method, our overview of air dispersion modelling for industries in India explains the general workflow, and how AERMOD works covers the model physics. The rest of this guide focuses on what is specific to refineries and petrochemical plants.
Refinery and Petrochemical Source Inventory
The source inventory is the foundation of the study. For refinery work it should be built unit by unit from the process flow diagrams, the fuel balance, the sulphur balance and the tank register, then cross-checked against stack monitoring and consent records. Our guide to emission inventories for dispersion modelling explains the general method.
Process Heaters and Boilers
Crude and vacuum distillation heaters, hydrotreater and reformer furnaces, hydrogen plant reformers and utility boilers are the largest group of point sources. They burn refinery fuel gas, natural gas, fuel oil or a mix. SO2 depends directly on the sulphur in the fuel: fuel gas H2S content after amine treating, or fuel oil sulphur content. NOx depends on burner design, firing rate and air preheat. Where heaters share a common stack, the stack is what gets modelled.
FCC Regenerator
The fluid catalytic cracking unit regenerator burns coke off the catalyst and is usually the largest single source of particulate matter (catalyst fines), and a major source of SO2, NOx and CO. Flue gas typically passes through cyclones, a CO boiler or full-burn regeneration, and an electrostatic precipitator, wet gas scrubber or third-stage separator. Emissions depend on feed sulphur and hydrotreating, so the basis must match the design crude basket.
Sulphur Recovery Unit and Tail Gas Incinerator
Acid gas from amine regeneration and sour water stripping goes to Claus sulphur recovery units. The residual sulphur compounds in the tail gas are either treated in a tail gas treating unit (TGTU) or sent straight to a thermal incinerator, which converts H2S and other reduced sulphur to SO2 before release through a tall stack. The SRU stack emission is a direct function of sulphur throughput and recovery efficiency, which makes it ideal for mass balance checking and for sensitivity tests on upset cases.
Flares: Elevated and Ground
Elevated flares handle emergency relief and process upsets; ground flares and enclosed ground flares are used where visual impact or radiation zoning matter. Purge and pilot flaring is small, but emergency flaring can release large amounts of SO2, NOx and CO for short periods.
Captive Power and Cogeneration
Many refineries run gas turbines with heat recovery steam generators, fuel oil or petcoke-fired boilers, or a coal-based captive plant. Coal and petcoke units bring PM, SO2 and NOx emissions comparable to a small thermal power station. Where this is the case, the approach in our guide to air dispersion modelling for thermal power plants applies to that part of the inventory.
Tank Farms and Loading
Crude, intermediate and product tanks emit VOCs through standing (breathing) losses and working losses. Floating roof tanks lose vapour through rim seals and deck fittings; fixed roof tanks vent through breather valves. Road tanker, rail wagon and marine loading of gasoline and naphtha can release significant VOC unless vapour recovery is installed. Benzene content in crude, reformate and gasoline makes this the main benzene source in most refineries.
Fugitive Equipment Leaks
Valves, flanges, pump seals, compressor seals, open-ended lines and relief valves leak small amounts of hydrocarbon. Across tens of thousands of components they add up to a substantial ground-level VOC source. Leak detection and repair (LDAR) data, where available, give a far better estimate than generic factors.
Wastewater Treatment and Other Area Sources
Oil-water separators, equalisation tanks, dissolved air flotation units and biological treatment basins release VOCs and H2S, and are a common cause of odour complaints. Coke, sulphur and catalyst handling and plant roads add particulates.
Petrochemical Units
Crackers have large furnace banks and decoking emissions; aromatics and polymer units have process vents, thermal oxidisers and tank farms, and product-specific organics such as 1,3-butadiene may matter. Our guide to AERMOD for pharmaceutical and chemical plants covers process vents and incinerators in more detail.
How Each Source Is Represented in AERMOD
AERMOD offers point, capped and horizontal point, flare, area (rectangular, circular and polygon), volume, line and open-pit sources. Our explainer on AERMOD source types describes each one; the table below shows the usual choices for refinery sources.
| Refinery source | Usual AERMOD representation | Key inputs |
|---|---|---|
| Heater and boiler stacks | POINT | Location, base elevation, height, inner diameter, exit velocity, exit temperature, emission rate (g/s) |
| FCC regenerator stack | POINT | As above, from design or CEMS data for the relevant feed case |
| SRU tail gas incinerator stack | POINT | As above, with SO2 from the sulphur balance |
| Gas turbine / HRSG stacks | POINT | As above, for each load case |
| Elevated flare | FLARE (or POINT with effective parameters) | Release height, total heat release rate, radiative heat loss fraction, emission rate |
| Enclosed ground flare | POINT | Vendor stack height, diameter, exit velocity and temperature |
| Stacks with rain caps or horizontal discharge | POINTCAP / POINTHOR | As POINT; AERMOD adjusts momentum |
| Floating roof tanks | AREACIRC or VOLUME | Tank diameter, release height near roof level, emission rate per unit area |
| Fixed roof tank vents | POINT (low flow) or VOLUME | Vent height, emission rate; flow is usually negligible |
| Process block fugitives | VOLUME or AREAPOLY | Block footprint, release height, initial lateral and vertical dimensions |
| ETP basins and separators | AREA / AREAPOLY | Basin footprint, release height near surface, emission rate per unit area |
| Loading gantry | VOLUME | Gantry dimensions, release height, emission rate |
| Plant roads and coke or sulphur handling | AREA, VOLUME or LINE | Road length and width, haul activity, emission rate |
Point Sources and Building Downwash
Refinery stacks are usually tall and hot, but heater stacks can be close to tall structures such as distillation columns, reactor structures and control buildings. BPIP-PRIME should be run with the significant structures digitised so that AERMOD can apply downwash where the stack is within the region of influence. Our guide to building downwash and BPIP explains how to decide which structures matter. Stack heights themselves should be checked against the CPCB formula, covered in stack height calculation under CPCB guidelines.
Flares and Effective Height Parameters
AERMOD's FLARE source type takes the flare tip height, the total heat release rate of the combusted gas (in cal/s), and the fraction of heat lost by radiation. AERMOD then calculates an effective release height that allows for flame length, an effective diameter, and applies fixed effective exit velocity and temperature values, so the modeller does not need to invent stack parameters. Where the radiative fraction is not available from the flare vendor, a commonly used screening value is 0.55, and the choice should be stated. The heat release rate is calculated from the flared gas flow and its net calorific value. The SO2 emission rate must reflect the sulphur content of the flared gas, and the heat release must come from the same flaring case. A small, sour, low-heat flaring event can give higher ground level concentrations than its size suggests, because plume rise is low.
Tank Farms, Fugitives and Area Sources
Low-level sources have little or no plume rise, so their impact falls close to the source and the fence line. Tank emissions are normally estimated with the US EPA AP-42 Chapter 7 methods for organic liquid storage, using tank dimensions, roof type, seal type, liquid properties, throughput and local meteorology. Each large tank, or a group of similar small tanks, is represented as a circular area or a volume source at roof height. Fugitive leaks are estimated by component count with average emission factors or, better, with screening value correlations from LDAR monitoring, then allocated to volume sources covering each process block. Initial dispersion dimensions for volume sources should follow the AERMOD user guide conventions, based on the block size and the height of the structures.
Terrain, Meteorology and Receptors
Coastal refineries need care with meteorology because AERMOD does not explicitly handle sea breeze or shoreline fumigation, so the met data choice needs justification; see meteorological data for air modelling in India and terrain and land use data for AERMOD. A dense fence line grid matters because low-level VOC and H2S sources peak there.
Pollutants to Model and the Standards They Are Compared With
| Pollutant | Main refinery sources | Comparison basis |
|---|---|---|
| SO2 | SRU incinerator, FCC, heaters on fuel oil, flares, coal or petcoke boilers | NAAQS 2009: 80 µg/m³ 24-hour, 50 µg/m³ annual |
| NOx as NO2 | Heaters, boilers, gas turbines, FCC | NAAQS 2009: 80 µg/m³ 24-hour, 40 µg/m³ annual |
| PM10 and PM2.5 | FCC catalyst fines, fuel oil and solid fuel firing, coke and sulphur handling, roads | NAAQS 2009: PM10 100 and 60 µg/m³, PM2.5 60 and 40 µg/m³ (24-hour, annual) |
| CO | FCC, flares, heaters | NAAQS 2009: 4 mg/m³ 1-hour, 2 mg/m³ 8-hour |
| Benzene | Tank farms, loading, fugitives, ETP, aromatics units | NAAQS 2009: 5 µg/m³ annual |
| Total VOC | Same as benzene | No Indian ambient standard; used for inventory and ozone precursor discussion |
| H2S | ETP, sour water, sulphur pits, fugitives, SRU upsets | No NAAQS; compare with health and odour guideline values, stating the source |
A few points about the comparison deserve emphasis.
- NO2 conversion. AERMOD predicts NOx; most of the NOx from a heater stack leaves as NO. Applying a Tier 2 or Tier 3 conversion method (ARM2, OLM or PVMRM) with representative ozone data gives a realistic NO2 estimate. Our guide to AERMOD NO2 modelling and NOx conversion explains the options and how to justify them.
- Averaging periods. Each standard must be compared with the right averaging period and statistic. Benzene uses the annual average from a multi-year or representative annual met file, not a short-term peak. See AERMOD averaging periods and NAAQS compliance.
- Secondary particulates. AERMOD models primary PM only. Sulphate and nitrate formed from SO2 and NOx are not included, so the report should say so and discuss the regional context qualitatively.
- H2S. India has no ambient standard for H2S. Commonly cited references include WHO guidance on odour annoyance and health-based values from other jurisdictions. The report should name the reference, match the averaging time, and discuss short averaging periods for odour. Our guide to odour dispersion modelling in India explains peak-to-mean factors and odour criteria.
The full set of ambient standards is in our NAAQS India reference. For measured VOC baselines, see VOC analysis in ambient air.
Indian Regulatory Context for Refinery Air Modelling
Environmental Clearance Category
Under the EIA Notification 2006, petroleum refining is listed as item 4(a) and petrochemical complexes based on processing of petroleum fractions and natural gas as item 5(c). Both are Category A activities, appraised by the sectoral Expert Appraisal Committee of MoEFCC. Expansions, crude capacity increases, new secondary units and fuel quality upgrade projects normally require an amendment or fresh EC, and air quality modelling forms a central part of the EIA. The notification has been amended many times, so the current consolidated text should be checked for any specific project. Our guide to air quality modelling for environmental clearance explains how the study fits into the EC process.
Standard Terms of Reference
The MoEFCC standard ToR for petroleum refining and petrochemicals typically asks for: a detailed emission inventory of all sources including flares and fugitive VOC; sulphur balance and sulphur recovery details; modelling of incremental GLCs for the relevant pollutants using an approved model with site-specific meteorology; isopleths superimposed on a map of the study area; the resultant concentrations after adding baseline; VOC and benzene monitoring in the baseline; an LDAR programme; and, for sites in industrial clusters, cumulative impact assessment. The project's own ToR letter should drive the scope.
Emission Standards Under the Environment (Protection) Rules
Schedule I of the Environment (Protection) Rules, 1986 contains specific emission standards for petroleum oil refineries, revised by a notification in 2008 (G.S.R. 186(E)). In general terms the refinery standards cover:
- Furnaces, boilers and captive power: limits for SO2, NOx, PM, CO and, for liquid fuel firing, nickel plus vanadium, set separately for gas firing and liquid fuel firing and for existing and new units, with limits on H2S in refinery fuel gas and sulphur in fuel oil. Continuous SO2 and NOx monitoring is required for larger units.
- FCC regenerator: limits for PM, NOx, CO, SO2 and nickel plus vanadium, with continuous monitoring.
- Sulphur recovery units: minimum sulphur recovery efficiency that increases with unit capacity and is tighter for new units, plus limits on H2S and other parameters in the tail gas incinerator exhaust, with continuous SO2 monitoring for larger units.
- Storage, loading and fugitives: design requirements for storage tanks by vapour pressure and capacity (floating roofs, secondary seals, vapour control), VOC recovery for gasoline and naphtha loading, and an LDAR programme with leak definitions and repair timelines.
- Flares: operating requirements including smokeless operation and monitoring.
The exact numerical limits, effective dates and conditions should be taken from the gazette text or the CPCB compilation of industry-specific standards, and from the project's existing consent and EC conditions, which are often stricter than the general standard. For modelling purposes, the defensible approach is to use the design emission rate where it is lower, and to show separately that the design case complies with the applicable standard. Using the limit itself as the emission rate is a conservative alternative.
Consent, Clusters and Critically Polluted Areas
State Pollution Control Boards issue CTE and CTO with their own conditions. Many refineries are in coastal industrial belts in Gujarat, Maharashtra, Odisha, Andhra Pradesh, Tamil Nadu and Kerala, or near inland industrial areas. Where neighbouring refineries, petrochemical complexes, fertiliser plants and power stations share the airshed, the ToR usually ask for a cumulative case. Our guide to cumulative air quality impact assessment in India covers how to gather neighbouring source data and avoid double counting with the baseline. Regional notes are in our pages on AERMOD modelling in Gujarat, Odisha and Chhattisgarh and Mumbai, Pune and Maharashtra.
Modelling Scenarios for Refinery Studies
A single normal operation run is rarely enough. A well-scoped study defines its scenarios at the start, agrees them with the proponent and states them in the report.
| Scenario | What it represents | Typical treatment |
|---|---|---|
| Existing normal operation | Current plant at design or permitted capacity | All sources at design or consent emission rates, annual and short-term averages |
| Proposed expansion only | New units in isolation | Incremental GLCs from new sources only |
| Post-expansion total | Existing plus new, minus any units being retired or modified | Full inventory, compared with NAAQS after adding baseline |
| Start-up and shutdown | Units running with controls not yet at design performance | Short-term averages for the affected sources only, with realistic duration |
| SRU or TGTU outage | Reduced sulphur recovery for a limited period | 24-hour SO2 sensitivity case, linked to an operating limit |
| Emergency flaring | Large relief event to the flare | Short-term FLARE run for SO2, NOx and CO at the relevant flaring rate |
| Cumulative | Project plus neighbouring industries | Neighbouring stacks from published or consent data |
Start-up, shutdown and upset scenarios concern short averaging periods. Running them for every hour of the met year gives the worst meteorological case. If the event is limited in duration, the report should relate the result to the 24-hour NAAQS averaging period.
Worked Example: SRU Stack SO2 Compared With NAAQS
The numbers below are illustrative only and are chosen to show the method. They do not represent any particular refinery.
Step 1: Emission Rate From the Sulphur Balance
A refinery expansion adds an SRU train with a design sulphur intake of 200 tonnes per day. With a TGTU, the design overall recovery efficiency is 99.5 per cent.
- Sulphur not recovered = 200 × (1 − 0.995) = 1.0 tonne per day.
- All of this is oxidised to SO2 in the incinerator. SO2 has twice the molecular weight of sulphur, so SO2 = 2.0 tonnes per day.
- Emission rate = 2,000,000 g ÷ 86,400 s = 23.1 g/s.
Step 2: Stack Parameters
The incinerator stack is 80 m high with an inner diameter of 1.8 m, an exit velocity of 15 m/s and an exit temperature of 573 K, located near the centre of the site with no downwash-relevant structures within its region of influence.
Step 3: Model Run and Increment
AERMOD is run with one year of site-representative meteorology from AERMET, AERMAP terrain and a nested receptor grid. In this illustration the model predicts:
- Maximum 24-hour SO2 increment: 9.6 µg/m³ at about 1.4 km from the stack.
- Maximum annual SO2 increment: 1.8 µg/m³.
Step 4: Add Background and Compare
The baseline monitoring station nearest the predicted maximum recorded a 98th percentile 24-hour SO2 of 18 µg/m³ and a seasonal mean of 11 µg/m³.
| Averaging period | Increment (µg/m³) | Background (µg/m³) | Resultant (µg/m³) | NAAQS (µg/m³) | Share of NAAQS |
|---|---|---|---|---|---|
| 24-hour | 9.6 | 18 | 27.6 | 80 | 35% |
| Annual | 1.8 | 11 | 12.8 | 50 | 26% |
The normal case complies comfortably.
Step 5: Test the TGTU Outage Case
Now suppose the tail gas treating unit trips and the SRU runs on Claus stages alone at 96.5 per cent recovery for a full day.
- Sulphur not recovered = 200 × 0.035 = 7.0 tonnes per day, so SO2 = 14.0 tonnes per day = 162 g/s, seven times the normal rate.
- If stack parameters are unchanged, the predicted concentration scales with the emission rate, so the 24-hour increment rises to about 9.6 × 7 = 67 µg/m³.
- Adding the 18 µg/m³ background gives about 85 µg/m³, above the 80 µg/m³ standard.
The conclusion is not that the project fails, but that the outage case needs a management response: a limit on the duration of operation without the TGTU, reduced acid gas intake or a switch to the parallel train during an outage. The modelling gives the evidence for that condition in the environmental management plan. In a real study the outage case would be rerun with the actual incinerator flue gas conditions rather than scaled, and the SRU would be modelled together with all other SO2 sources for the post-expansion total.
Scope-of-Work Checklist for Procurement Teams
A clear scope in an enquiry or tender avoids variation claims and makes bids comparable. Adapt the checklist below.
- Purpose and regulatory driver: EC for new project or expansion, ToR reference, CTE or CTO, EC compliance, or an internal environmental audit.
- Model and version: AERMOD with AERMET and AERMAP, with the current US EPA regulatory version, and BPIP-PRIME for downwash.
- Source inventory responsibility: who compiles stack data, the sulphur balance, tank register and LDAR data, and who signs off emission rates.
- Sources included: all stacks, FCC, SRU, flares, captive power, tank farms, loading, fugitives, ETP, roads and handling, with any exclusions stated.
- Pollutants: SO2, NOx as NO2 with the conversion method, PM10, PM2.5, CO, benzene, VOC, H2S and any product-specific organics.
- Scenarios: existing, expansion only, post-expansion total, start-up and shutdown, SRU or TGTU outage, emergency flaring and cumulative.
- Meteorology: period, source of surface and upper air data (site station, IMD, prognostic), and who supplies on-site data.
- Terrain and receptors: study area radius, grid spacing, fence line receptors and named sensitive receptors such as villages, schools and hospitals.
- Baseline integration: which monitoring stations and statistics will be added to increments.
- Deliverables: report chapter in EIA format, isopleth maps on a base map, input and output files, emission inventory tables and a QA record.
- Review support: responses to EAC or SEAC queries and reruns, with the number of iterations included.
- Schedule: realistic turnaround that allows time for data collection, which is usually the slowest step.
Our guides to how to outsource air dispersion modelling and what an AERMOD modelling subcontractor does cover contracting in more detail, and AERMOD modelling cost explains which scope items drive effort.
Common Review Queries on Refinery Modelling Studies
| Query from the committee or reviewer | What a good report already contains |
|---|---|
| Is the sulphur balance consistent with the SO2 emissions modelled? | Unit-wise sulphur balance from crude to products, recovered sulphur and emissions |
| Have flares been modelled, and under what flaring rate? | FLARE inputs for continuous and emergency cases with heat release and gas composition |
| What is the basis for VOC and benzene emissions from tanks and fugitives? | AP-42 calculations, tank list, component counts or LDAR data |
| Why was NO2 taken as a fraction of NOx? | Named conversion method, ozone data source and justification |
| How does the coastal setting affect the met data? | Met station distance and exposure, discussion of sea breeze and limitations |
| Where do the maximum GLCs fall relative to habitations? | Isopleths with villages marked and values at sensitive receptors |
| Have neighbouring units been included? | Cumulative case with a list of neighbouring sources and data sources |
| What happens during SRU or TGTU outage? | Sensitivity run and the operating condition proposed |
| Is H2S an odour risk? | H2S sources, guideline used, short-term analysis and mitigation |
| How reliable are the predictions? | Model limitations and a comparison with monitored data where possible |
The general limitations of the model, and how to discuss them honestly, are covered in how accurate is AERMOD, and a reviewer-style checklist is in our guide to QA/QC of air dispersion reports.
How DSTechnoverse Helps
We carry out AERMOD studies for refineries, petrochemical complexes and allied units, covering stack, flare, tank farm, fugitive and ETP sources, sulphur balance checks, NO2 conversion, start-up and upset scenarios and cumulative cases for cluster locations. We work directly with industries and as a white-label partner for EIA consultancies, remotely across India. Details of the study scope are on our AERMOD air dispersion modelling service page, and supporting baseline and data work is available through EIA data analysis outsourcing. To discuss a refinery or petrochemical project, contact our team.
Frequently Asked Questions
Is AERMOD accepted for refinery EIA studies in India?
Yes. AERMOD is widely used in Indian EIA reports for refineries and petrochemical projects and is accepted by the Expert Appraisal Committee when it is run with representative meteorology, terrain and a complete emission inventory. The ToR usually asks for an approved model rather than naming one, so the report should state the model version, the regulatory options used and why the setup suits the site.
How should an elevated flare be modelled in AERMOD?
Use the FLARE source type with the flare tip height, the total heat release rate of the flared gas and the radiative heat loss fraction. AERMOD then computes the effective release height and diameter. The SO2 emission rate comes from the sulphur content of the flared gas. Model continuous and emergency flaring as separate cases, because their emission rates and plume rise differ greatly.
Does a refinery study need to model benzene?
Usually yes. Benzene has an Indian ambient standard of 5 µg/m³ as an annual average, and refinery tank farms, loading operations, fugitive leaks and effluent treatment are significant sources. The ToR for refining and petrochemical projects generally ask for VOC and benzene in the baseline. Model the annual average from tank and fugitive emission estimates and add the measured baseline.
How are tank farm emissions estimated for modelling?
Tank emissions are normally calculated with the US EPA AP-42 Chapter 7 methods, using tank dimensions, roof and seal type, stored liquid properties, annual throughput and local temperature data. The results give annual emissions per tank, which are converted to grams per second and assigned to circular area or volume sources at roof height. Benzene is calculated from its fraction in the vapour.
What is the main SO2 source in a refinery model?
It depends on the configuration. In many refineries the SRU tail gas incinerator, the FCC regenerator and any heaters or boilers burning fuel oil or petcoke dominate. Where fuel gas is well treated and the SRU has tail gas treating, total SO2 can be modest. A unit-wise sulphur balance shows which sources matter and provides a check on the modelled emission rates.
Is H2S compared with any Indian ambient standard?
No. NAAQS 2009 does not include hydrogen sulphide. Studies compare predicted H2S with health-based and odour guideline values from recognised sources such as WHO guidance, matching the averaging period. Because odour responds to short peaks, the assessment should consider short averaging periods and peak-to-mean ratios, and focus on the ETP, sour water and sulphur handling areas.
Do start-up and shutdown emissions need to be modelled?
They are increasingly asked about, particularly for SRU, FCC and flare systems. The usual approach is a short-term sensitivity run for the affected sources at their start-up or upset emission rates, with a clear statement of the expected duration and frequency. The result supports operating procedures and limits in the environmental management plan rather than a single compliance figure.
How is cumulative impact handled in a refinery cluster?
Neighbouring refineries, petrochemical plants, power stations and fertiliser units within the study area are added to the model using emission data from their EC documents, consent records or published compliance reports. The baseline already contains their present contribution, so care is needed to avoid double counting. Cumulative impacts matter most for proposed or recently commissioned neighbouring units.
How long does a refinery AERMOD study take?
The modelling itself takes days to a few weeks, depending on the number of sources and scenarios. The slowest step is usually gathering the inventory: stack data, sulphur balance, tank register, component counts and neighbouring source data. Agreeing the scenarios and data responsibilities at the start shortens the programme and reduces rework after appraisal queries.
Need an AERMOD study or AERMOD software? DSTechnoverse runs regulatory AERMOD modelling studies for EC, CTE and expansion applications, for industries and as a white-label partner for EIA consultancies, and provides AERMOD Studio, our AERMOD software, personalised for your firm. We are based in Indore, Madhya Pradesh and work across India. Talk to our team.
Related articles
- Air Dispersion Modelling for Steel Plants in India: Sources, Pollutants and AERMOD Setup
- Air Dispersion Modelling Tender: A Model AERMOD Scope of Work, Evaluation Criteria and Bidder Guide
- Air Dispersion Modelling for Industries in India: A Compliance Guide
- Air Dispersion Modelling for Pharmaceutical and Chemical Plants in India