Air dispersion modelling is a scientific method used to predict how pollutants released from a source travel through the atmosphere and what concentrations they produce at ground level and beyond. The reliability of any model result depends almost entirely on the quality of the data fed into it. A well-run model with poor inputs will produce confident but misleading numbers, while a modest model with sound, well-characterised inputs will support defensible decisions.
This reference article explains the inputs required for air dispersion modelling, organised into the five main categories that practitioners assemble for every study: source, meteorological, terrain, building, and receptor data. It is written for environmental professionals, project proponents, and students working within the Indian regulatory framework administered by the Central Pollution Control Board (CPCB), the Ministry of Environment, Forest and Climate Change (MoEFCC), and the State Pollution Control Boards (SPCBs).
What are the inputs required for air dispersion modelling?
In short, air dispersion modelling requires five categories of input data: emission source characteristics, meteorological data, terrain and land-use information, nearby building dimensions, and receptor locations. Together these describe what is emitted, how the atmosphere transports and dilutes it, and where the resulting concentrations must be assessed.
Each category answers a distinct physical question. Source data describes the pollutant and how it leaves the source. Meteorological data governs transport and dilution. Terrain and land-use control flow behaviour and turbulence. Building data captures aerodynamic downwash. Receptors define the grid of points where predicted concentrations are calculated and compared against the National Ambient Air Quality Standards (NAAQS).
The sections below treat each category as a checklist you can work through when scoping a modelling study for an Environmental Impact Assessment (EIA), a Consent to Establish or Operate application, or a compliance review.
Source inputs
Source characterisation is the foundation of the model. Errors here propagate directly into every predicted concentration. Sources are usually grouped as point sources (stacks), area sources (open storage, ponds, material handling yards), volume sources (fugitive emissions from buildings or lines), and line sources (roads, conveyors).
For each stack or point source, the model typically needs the following.
| Parameter | Description | Typical unit |
|---|---|---|
| Emission rate | Mass of pollutant released per unit time | grams per second |
| Stack height | Height above ground of the release point | metres |
| Stack inside diameter | Internal diameter at the exit | metres |
| Exit gas velocity | Speed of the flue gas leaving the stack | metres per second |
| Exit gas temperature | Temperature of the released gas | kelvin |
| Location | Easting and northing of the stack base | metres (UTM) |
| Base elevation | Ground elevation at the stack | metres above sea level |
A few practical notes on source inputs.
- Emission rates should come from stack monitoring, mass balance, or recognised emission factors, and must reflect the pollutant of interest, commonly particulate matter (PM10 and PM2.5), sulphur dioxide, oxides of nitrogen, and carbon monoxide.
- Exit velocity and temperature drive plume rise. A hot, fast plume rises higher and disperses more before reaching the ground, so these values materially affect predictions.
- For area and volume sources, additional parameters such as source dimensions, release height, and initial dispersion coefficients are required.
- Where multiple stacks exist, each is entered separately so the model can sum their combined contribution at every receptor.
Meteorological inputs
Meteorology controls how the plume is carried and diluted, and it is usually the most demanding category to assemble. Steady-state Gaussian models such as AERMOD require a pre-processed meteorological dataset built from surface observations and upper-air soundings.
Surface meteorological parameters generally include the following.
- Wind speed and wind direction, ideally hourly, over a full representative year.
- Ambient temperature.
- Cloud cover.
- Relative humidity.
- Atmospheric pressure.
Upper-air data, in the form of a morning radiosonde sounding, is needed to characterise the vertical temperature profile and mixing height. The meteorological pre-processor combines surface and upper-air data to derive the parameters the dispersion model actually uses, including friction velocity, Monin-Obukhov length, convective velocity scale, mixing height, and surface heat flux.
A representative dataset matters as much as a complete one. Consider these points when selecting meteorological inputs.
- 1Use at least one full year of continuous hourly data, or five years where guidance calls for it, so that seasonal variation and worst-case conditions are captured.
- 2Prefer site-specific measurements from an on-site weather station where the study scale justifies it. In many Indian EIA studies, a season of site data is collected alongside secondary data from the India Meteorological Department (IMD).
- 3Check data capture rates and fill gaps using accepted substitution procedures, because low capture undermines the credibility of results.
- 4Assign surface characteristics, discussed below, that match the land use around the meteorological station, not only around the source.
A model output is only as representative as the year of weather behind it. Spending effort on a defensible meteorological dataset is rarely wasted.
Terrain and land-use inputs
Terrain determines whether a plume travels over flat ground or interacts with hills and valleys, and land use governs surface roughness and turbulence. Both influence how quickly a plume mixes toward the ground.
The main terrain and surface inputs are as follows.
- Digital elevation data for the modelling domain, used to assign ground elevation to every source and receptor. In flat terrain this step can be simplified, but in undulating or hilly regions it is essential, because elevated receptors can intercept a plume that would otherwise pass overhead.
- Surface roughness length, which reflects how rough the ground is, ranging from low values over water and open land to higher values over forest and built-up areas.
- Albedo, the fraction of solar radiation reflected by the surface, which affects heating and convective mixing.
- Bowen ratio, describing the partition of surface heat between sensible and latent forms, which depends on moisture and vegetation.
These surface parameters are usually assigned by sector and by season around the meteorological station, since land use and its thermal behaviour change through the year, particularly between the monsoon and dry seasons in India.
Building inputs
When a stack is located close to buildings, the airflow disturbed by those structures can pull the plume downward into the turbulent wake on the lee side. This effect, known as building downwash or aerodynamic downwash, can sharply increase ground-level concentrations near the source and is often the difference between compliance and exceedance.
To evaluate downwash, the model needs the physical dimensions and positions of nearby structures.
- Building height.
- Building length and width, or the full footprint outline.
- Location and orientation of each building relative to the stack.
A widely used rule of thumb is that structures within roughly five to ten stack heights of a source may influence its plume and should be included. A dedicated building profile tool processes these dimensions into direction-specific downwash parameters that the dispersion model then applies. Omitting relevant buildings is a common source of under-prediction, so this category deserves careful attention even though it is sometimes overlooked.
Receptor inputs
Receptors are the points where the model calculates concentrations. They define the spatial resolution of the study and determine whether local hotspots are captured.
Typical receptor arrangements include the following.
- A Cartesian or polar grid covering the study area, often extending to the standard EIA study radius around the project, with finer spacing near the source where gradients are steep and coarser spacing at the domain edge.
- Discrete receptors placed at sensitive locations such as residential clusters, schools, hospitals, and ecologically sensitive areas.
- Receptors aligned with existing ambient monitoring stations, so that predicted values can be compared with measured baseline concentrations.
Each receptor carries a location and a ground elevation. In elevated terrain, a receptor may also carry a hill height scale so the model can treat plume-terrain interaction correctly. The predicted concentrations at these receptors are then compared against the NAAQS averaging periods, such as annual and 24-hour values for particulate matter and sulphur dioxide, to judge compliance.
Baseline and background concentrations
One further input links modelling to regulatory assessment. Model predictions represent the incremental contribution of the project. To assess total ambient impact, the predicted increment is added to the existing background concentration measured during baseline monitoring. The combined value is what should be compared against the NAAQS in an EIA. Baseline data therefore functions as an essential companion input, even though it is not part of the dispersion calculation itself.
Input checklist at a glance
| Category | Core inputs |
|---|---|
| Source | Emission rate, stack height, diameter, exit velocity, exit temperature, location, base elevation |
| Meteorological | Hourly surface data, upper-air sounding, derived boundary-layer parameters |
| Terrain and land use | Elevation data, surface roughness, albedo, Bowen ratio |
| Building | Height, footprint, orientation of nearby structures |
| Receptor | Grid and discrete receptors, elevations, sensitive locations |
| Baseline | Measured background concentrations for total-impact assessment |
Why input quality decides the outcome
Air dispersion modelling is a data-driven exercise. The physics embedded in the model is fixed, but the answer changes with every input value. A defensible study begins by verifying that source parameters reflect actual operations, that the meteorological year is representative, that terrain and surface characteristics match the site, that all influential buildings are accounted for, and that receptors are placed where people and ecosystems actually are.
Working systematically through the five input categories, alongside baseline data, gives assessors, regulators, and the public confidence that predicted concentrations and their comparison with the NAAQS are meaningful rather than merely numerical.
DSTechnoverse supports proponents and consultants in assembling, validating, and applying these inputs for air dispersion modelling studies within the Indian regulatory framework.
Further Reading
- The AERMOD input data checklist
- How to prepare an emission inventory for dispersion modelling
- Receptor grid design in dispersion modelling
- Meteorological data for air modelling in India
- AERMOD air dispersion modelling service
Frequently Asked Questions
How much meteorological data is needed? Hourly data covering at least the baseline monitoring season is common for an EIA. A full year or more gives a more representative picture of worst-case conditions; data capture and calm hours should be checked before use.
What if the plant is not built yet? Emission rates come from design data, equipment vendor guarantees, applicable emission standards or recognised emission factors, and the basis for each value is stated in the report.
How fine should the receptor grid be? Fine enough near the sources to capture the true maximum, typically with closer spacing near the fence line and coarser spacing further out, plus discrete receptors at villages, schools, hospitals and other sensitive locations.